In the new revision of AMS2750F, standard error limit requirements have been removed from Table 1. The error of ±4°F or ±0.75% is no longer permitted.

Base metal thermocouple permitted allowance for SAT, TUS, Load and furnace thermocouples is now ±2°F or ±0.4% of the reading (with the exception of type E & T thermocouples). 

Conrad Kacsik provides superior quality thermocouples in accordance with AMS2750F.